It’s not incredibly enlightening, but here’s the owner’s manual for the Imperial IFS series as well: http://download.partstown.com/is-bin/intershop.static/WFS/Reedy-PartsTown-Site/-/en_US/manuals/IMP-IFS_iom.pdf. Circuit breaker needs to be reset – See if the circuit breaker needs to be reset. Turn the valve counter clockwise to open the valve and to increase the flow of gas. 3 Common Commercial Deep Fryer Problems 1. Look to see if the drain valve is fully closed, if you have a filtration system. If you ever run into a small issue, don’t let it stop you. Not like most fryers. 2. The thermostat is probably gone bad or it could be the switch. Cannot find the manual, Pilot light will stay lit. Europro deep fryer f1061 won't turn on? Test for gas valve power to the main,  and that the pilot sensing has voltage. 6 Posts Archives. Other than that there are 3 things that control the gas, the thermostat, the gas valve itself and the high limit. Favorite Answer. I would test all 3 of those components and ensure that your burners are clean. Follow the specific instructions below from Anets. Sign up today! Perfect Fry fryers display error messages when certain issues occur. Find out what we're up to with the Parts Town newsletters. Lv 6. If oil excessively spills into the tray, check for the possible causes below: If the exterior surface is unusually hot, look for the following: If you notice excessive smoking or foaming coming from the unit, check for the possible causes below: If food doesn’t come out on PFC, PFA and DSA models, the following could have occurred: If you have trouble loading food on PFC, PFA and DSA models, look for the possible causes below: If the spin basket on an SFC model is too noisy or vibrates, it might not be loaded evenly. When I tried to turn on the fryer the ignite won’t lit, I don’t know if it is the thermostat or the thermopile causing problem. Its a very old unit not sure if the wires need replaced. 1 Answer. When it comes to frying food, Perfect Fry has been a game changer in the foodservice industry. Won’t Turn On. If you notice that your fryer’s temperature seems off, use a thermometer to check. When lighting a manual pilot system, sufficient time must be allowed for the pilot flame to heat the thermocouple. Check out our selection of Perfect Fry manuals for assistance. Since 1937, Anets has been on the cutting edge of fryers. Check to see if the flexible gas hose is properly connected and that the fryer is plugged in. This field is for validation purposes and should be left unchanged. Sometimes it’s just the quick connect behind the unit. Remove some oil so it’s not filled above the cold oil line. It was working perfectly fine. Turn the knob slowly until the valve is all the way open. An open valve handle -- even just slightly open -- will not allow it to work. Power then comes back to the pilot coil of the gas valve. 9 years ago. The valve handle must be closed to allow power to reach the gas valve as it interacts with a microswitch. March 8, 2017 at 12:00 am. Burner Malfunctioning. Anets Deep Fryer Troubleshooting Matthew G / Commercial Fryers, Troubleshooting / August 5. Answer Save. That’s true on the standard, but on the electronic it is not. Being computer controlled,  You may have a board problem. Visit our store. Not a fan of Imperial’s control system. If the fryer has no pilot light lit, That means that either there is no gas, or no power to keep the pilot valve open, Set you meter on DC millivolts. Home › Forums › Archives › In my IFS-40 WAT Imperial deep fryer the gas will not light what can I Do. Relevance. Incorrect Temperature . Jo Ann. Turned it on today and it's not working. Below are potential issues and tips to help you make an accurate diagnosis with your fryer. Turn gas valve on the deep fryer to PILOT position. techjoeb. I have a pitco double natural gas deep fryer that seems to have a problem. Light the grill. Surprised the hell out of me too. Find out what we're up to with the Parts Town newsletters. Member. Never heard of a fryer that didn’t extinguish the pilot in an over temp condition. Are you looking for restaurant parts? Since 1937, Anets has been on the cutting edge of fryers. Note that the millivolt generator (Thermopile) is connected to the common of the gas valve and another wire to the high limit. If you ever run into a small issue, don’t let it stop you. Our Anets deep fryer troubleshooting guide will help you quickly diagnose a potential problem quickly. The instructions and codes below are for DSA, DSE, PFA, PFC, PFM and SFC models. Many restaurants and commercial kitchens use its gas and electric units to fry everything from chicken wings to crispy apps. Faulty Burners. Here is the parts manual:  http://download.partstown.com/is-bin/intershop.static/WFS/Reedy-PartsTown-Site/-/en_US/manuals/IMP-IF-Series_pm.pdf  I hope this helps. Are you looking for restaurant parts? If the temperature is off by 10 degrees Fahrenheit, check if the fryer’s thermostat needs calibration. Cannot find the manual, http://download.partstown.com/is-bin/intershop.static/WFS/Reedy-PartsTown-Site/-/en_US/manuals/IMP-IF-Series_pm.pdf. If not, the fuse might have to be replaced. If your fryer is not lighting I would tell you this first: Be sure you are familiar and able to mess with flammable gas if so, I would check the gas supply first. After pilot is lit, continue to hold down the gas valve for about one minute. Coronavirus (COVID-19) Resources for Restaurants & Commercial Kitchens, 4 Key Convenience Store Trends to Explore, CES 2020: The Major Foodservice & Restaurant Innovations from the Show, Southbend Convection Oven Troubleshooting. While it’s rare, small issues can pop up after years and years of daily use. Pilot light will stay lit. This is my first time operating the deep fryer and so I am really clueless of what is going on. Visit our store. For more troubleshooting and maintenance tips, check out our collection of Anets manuals. This site is protected by reCAPTCHA and the Google. March 8, 2017 at 3:48 pm. If the fryer won’t turn on when you press the ON/OFF key, check for the following causes: Not plugged in – See if the power cord was accidentally knocked out of the outlet and plug it back in. Make sure the heat switch is on and it is set to a cook temperature. Coronavirus (COVID-19) Resources for Restaurants & Commercial Kitchens, 4 Key Convenience Store Trends to Explore, CES 2020: The Major Foodservice & Restaurant Innovations from the Show, Southbend Convection Oven Troubleshooting. If it’s different from the temperature you’ve set it on, then the thermostat likely needs to be repaired or replaced. If the fryer won’t turn on when you press the ON/OFF key, check for the following causes: If the fryer is on but not heating, look for the potential issues below: If the fryer baskets won’t low into the oil or rise out of it, see if the following issues are present: Whenever food floats out of the basket, you might have filled too much oil into the vat. But don’t worry! Member. The won't even turn on. The LCD screen will display the message “SYSTEM ERROR PLEASE CHECK” followed by one of these prompts: Need more troubleshooting help? Am really appreciate you taking the time help the community. Sign up today! Depress gas valve, wait 30 seconds, and hold it down while lighting the pilot. Their line of ventless, countertop commercial fryers are not only used in restaurants, but they’re also ideal for portable kitchens, catering stations, fairs and temporary locations. Many restaurants and commercial kitchens use its gas and electric units to fry everything from chicken wings to crispy apps. It's not getting hot either. We have Perfect Fry troubleshooting tips and a list of error codes to help you identify the cause quickly. If the pilot is working, most likely it is the thermostat or the hi limit. In my IFS-40 WAT Imperial deep fryer the gas will not light what can I Do. guest. Make sure the lid is still open, then turn the control knob for the front burner until it is all the way in the “High” position. Can you please help. Make sure it’s loaded evenly. Its a very old unit not sure if the wires need replaced. I believe on the Imperial the pilot will stay lit with a over-temp trip. Use a long grill lighter to avoid contact with hands.

Cat Movies List, Jtac Local 46, Spicy Braised Tofu, 24 Pack Of Heineken, Fall Festivals 2020 Nj, How To Make Oatmeal,